Reference |
SR01 |
1.01 |
Brand |
DEC IMPIANTI |
1.02 |
Type |
Solvent recovery plant |
1.03 |
Functioning |
By activated carbons with distiller |
1.04 |
Year |
2005 |
1.05 |
Solvents |
Ethyl acetate > 97,0 % by weight |
1.06 |
Max. air flow to the plant |
95.000 Nm3/h at 0° C |
1.07 |
Min. air flow to the plant |
15.000 Nm3/h at 0° C |
1.08 |
Air temperature to the plant |
35° ÷ 55° C |
1.09 |
Max. solvents flow |
475 kg/h |
1.10 |
Average solvents flow |
350 kg/h |
1.11 |
Max. concentration (L.E.L.) |
< 20 % |
1.12 |
Production output of distiller |
300 kg/h (in a repeated cycle) |
1.13 |
Tanks of activated carbons |
No. 4 |
1.14 |
Distillation columns |
No. 1 |
1.15 |
Altitude |
50 ÷ 100 m a.s.l. |
1.16 |
Outside temperature (outdoor) |
-5° ÷ +40° C |
1.17 |
Field of application |
Rotogravure and flexo printing for flexible packaging |
1.18 |
Shifts of 8 working hours per year |
From 2200 to 6720 |
1.19 |
More information |
Immediately available |